UCF STIG Viewer Logo
Changes are coming to https://stigviewer.com. Take our survey to help us understand your usage and how we can better serve you in the future.
Take Survey

The BIG-IP appliance must be configured to enforce a 60-day maximum password lifetime restriction.


Overview

Finding ID Version Rule ID IA Controls Severity
V-60161 F5BI-DM-000127 SV-74591r1_rule Medium
Description
Any password, no matter how complex, can eventually be cracked. Therefore, passwords need to be changed at specific intervals. One method of minimizing this risk is to use complex passwords and periodically change them. If the network device does not limit the lifetime of passwords and force users to change their passwords, there is the risk that the passwords could be compromised. This requirement does not include emergency administration accounts that are meant for access to the network device in case of failure. These accounts are not required to have maximum password lifetime restrictions.
STIG Date
F5 BIG-IP Device Management 11.x Security Technical Implementation Guide 2019-10-01

Details

Check Text ( C-61015r1_chk )
Verify the BIG-IP appliance is configured to use a properly configured authentication server that enforces a 60-day maximum password lifetime.

Navigate to the BIG-IP System manager >> System >> Users >> Authentication.

Verify "Authentication: User Directory" is configured for an approved remote authentication server that enforces a 60-day maximum password lifetime restriction.

If the BIG-IP appliance is not configured to use a properly configured authentication server that enforces a 60-day maximum password lifetime, this is a finding.
Fix Text (F-65749r1_fix)
Configure the BIG-IP appliance or its associated authentication server to enforce a 60-day maximum password lifetime.