UCF STIG Viewer Logo
Changes are coming to https://stigviewer.com. Take our survey to help us understand your usage and how we can better serve you in the future.
Take Survey

The BIG-IP appliance must be configured to protect audit tools from unauthorized access.


Overview

Finding ID Version Rule ID IA Controls Severity
V-60133 F5BI-DM-000079 SV-74563r1_rule Medium
Description
Protecting audit data also includes identifying and protecting the tools used to view and manipulate log data. Therefore, protecting audit tools is necessary to prevent unauthorized operation on audit data. Network devices providing tools to interface with audit data will leverage user permissions and roles identifying the user accessing the tools and the corresponding rights the user enjoys in order to make access decisions regarding the access to audit tools. Audit tools include, but are not limited to, vendor-provided and open source audit tools needed to successfully view and manipulate audit information system activity and records. Audit tools include custom queries and report generators.
STIG Date
F5 BIG-IP Device Management 11.x Security Technical Implementation Guide 2017-06-27

Details

Check Text ( C-60959r1_chk )
Verify the BIG-IP appliance protects audit tools from unauthorized access.

Navigate to the BIG-IP System manager >> System >> Logs >> Configuration >> Options.

Verify authorized access is configured for each role under "Log Access".

If the BIG-IP appliance is not configured to protect its audit tools from unauthorized access, this is a finding.
Fix Text (F-65691r1_fix)
Configure the BIG-IP appliance to protect audit tools from unauthorized access.