Finding ID | Version | Rule ID | IA Controls | Severity |
---|---|---|---|---|
V-60205 | F5BI-DM-000201 | SV-74635r1_rule | Medium |
Description |
---|
The loss of connectivity to a particular authoritative time source will result in the loss of time synchronization (free-run mode) and increasingly inaccurate time stamps on audit events and other functions. Multiple time sources provide redundancy by including a secondary source. Time synchronization is usually a hierarchy; clients synchronize time to a local source while that source synchronizes its time to a more accurate source. The network device must utilize an authoritative time server and/or be configured to use redundant authoritative time sources. This requirement is related to the comparison done in CCI-001891. DoD-approved solutions consist of a combination of a primary and secondary time source using a combination or multiple instances of the following: a time server designated for the appropriate DoD network (NIPRNet/SIPRNet); United States Naval Observatory (USNO) time servers; and/or the Global Positioning System (GPS). The secondary time source must be located in a different geographic region from the primary time source. |
STIG | Date |
---|---|
F5 BIG-IP Device Management 11.x Security Technical Implementation Guide | 2017-03-02 |
Check Text ( C-61059r1_chk ) |
---|
Determine if the BIG-IP appliance is configured to synchronize internal information system clocks with the primary and secondary time sources located in different geographic regions using redundant authoritative time sources. Navigate to the BIG-IP System manager >> Configuration >> Device >> NTP. Verify there is a primary time source and a secondary time source configured that are in different geographic regions. If the BIG-IP appliance is not configured to synchronize internal information system clocks with the primary and secondary time sources located in different geographic regions using redundant authoritative time sources, this is a finding. |
Fix Text (F-65793r1_fix) |
---|
Configure the BIG-IP appliance to synchronize internal information system clocks with the primary and secondary time sources located in different geographic regions using redundant authoritative time sources. |