The BIG-IP appliance must be configured to limit the number of concurrent sessions to one (1) for each administrator account and/or administrator account type.


Overview

Finding ID Version Rule ID IA Controls Severity
V-60091 F5BI-DM-000003 SV-74521r1_rule Medium
Description
Device management includes the ability to control the number of administrators and management sessions that manage a device. Limiting the number of allowed administrators and sessions per administrator is helpful in limiting risks related to DoS attacks. This requirement addresses concurrent sessions for administrative accounts and does not address concurrent sessions by a single administrator via multiple administrative accounts. The maximum number of concurrent sessions should be defined based upon mission needs and the operational environment for each system.
STIG Date
F5 BIG-IP Device Management 11.x Security Technical Implementation Guide 2017-03-02

Details

Check Text ( C-60853r1_chk )
Verify the BIG-IP appliance is configured to limit the number of concurrent sessions to one (1) for all administrator accounts and/or administrator account types.

Navigate to the BIG-IP System manager >> System >> Preferences.

Set "System Settings:" to "Advanced".

Verify "Maximum HTTP Connections To Configuration Utility" is set to the organization-defined number of concurrent sessions.

If neither of these configurations is present, this is a finding.
Fix Text (F-65585r1_fix)
Configure the BIG-IP appliance either to limit the number of concurrent sessions to one (1) for all administrator accounts and/or administrator account types.