UCF STIG Viewer Logo
Changes are coming to https://stigviewer.com. Take our survey to help us understand your usage and how we can better serve you in the future.
Take Survey

Receive Connector Maximum Hop Count must be 60.


Overview

Finding ID Version Rule ID IA Controls Severity
V-33579 Exch-2-741 SV-43999r2_rule ECSC-1 Low
Description
Email system availability depends in part on best practices strategies for setting tuning configurations. This setting controls the maximum number of hops (email servers traversed) a message may take as it travels to its destination. Part of the original Internet protocol implementation, the hop count limit prevents a message being passed in a routing loop indefinitely. Messages exceeding the maximum hop count are discarded undelivered. Recent studies indicate that virtually all messages can be delivered in fewer than 60 hops. If the hop count is set too low, messages may expire before they reach their destinations. If set too high, an undeliverable message may cycle between servers, raising the risk of network congestion.
STIG Date
Exchange 2010 Edge Transport Server STIG 2015-03-10

Details

Check Text ( C-41685r3_chk )
Obtain the Email Domain Security Plan (EDSP) and locate the value for 'Receive Connectors”.
Open the Exchange Management Shell and enter the following command:

Get-ReceiveConnector | Select name, MaxHopCount

If the value of 'MaxHopCount' is set to 60 this is not a finding.

If the value of 'MaxHopCount' is set to a value other than 60 and has signoff and risk acceptance in the EDSP, this is not a finding.
Fix Text (F-37470r1_fix)
Open the Exchange Management Shell and enter the following command:

Set-ReceiveConnector -MaxHopCount 60

If an alternate value is desired, obtain signoff with risk acceptance and document in the EDSP.