UCF STIG Viewer Logo
Changes are coming to https://stigviewer.com. Take our survey to help us understand your usage and how we can better serve you in the future.
Take Survey

Encryption must be used for OWA access.


Overview

Finding ID Version Rule ID IA Controls Severity
V-33585 Exch-1-203 SV-44005r1_rule ECSC-1 Medium
Description
This setting controls whether client machines should be forced to use secure channels to communicate with this virtual directory. If this feature is enabled, clients will only be able to communicate with the directory if they are capable of supporting secure communication with the server. The use of secure communication prevents eavesdroppers from reading or modifying communications between servers and clients. The network and DMZ STIG identify criteria for OWA and Public Folder configuration in the network, including CAC enabled pre-authentication through an application firewall proxy. Failure to require secure connections on a web site increases the potential for unintended eavesdropping or data loss.
STIG Date
Exchange 2010 Client Access Server STIG 2013-01-03

Details

Check Text ( C-41692r1_chk )
Open the Windows PowerShell Modules and enter the following command:

Get-WebBinding

Review the website and verify port 443 is used for OWA access. If not, this is a finding.
Fix Text (F-37477r1_fix)
Configure the OWA site to require SSL port 443.