UCF STIG Viewer Logo

The audit system must alert the SA when the audit storage volume approaches its capacity.


Overview

Finding ID Version Rule ID IA Controls Severity
V-22375 GEN002730 SV-26022r1_rule ECAT-1 Medium
Description
An accurate and current audit trail is essential for maintaining a record of system activity. If the system fails, the SA must be notified and must take prompt action to correct the problem. Minimally, the system must log this event and the SA will receive this notification during the daily system log review. If feasible, active alerting (such as e-mail or paging) should be employed consistent with the site’s established operations management systems and procedures.
STIG Date
Draft AIX Security Technical Implementation Guide 2011-08-17

Details

Check Text ( C-29208r1_chk )
Determine if the audit system is configured to alert the SA when the audit storage volume approaches capacity. If it does not, this is a finding.
Fix Text (F-26228r1_fix)
Configure the audit system to alert the SA when the audit storage volume approaches capacity.