UCF STIG Viewer Logo

The DBN-6300 must record time stamps for audit records that meet a granularity of one second for a minimum degree of precision.


Overview

Finding ID Version Rule ID IA Controls Severity
V-76995 DBNW-DM-000104 SV-91691r1_rule Medium
Description
Without sufficient granularity of time stamps, it is not possible to adequately determine the chronological order of records. Time stamps generated by the application include date and time. Granularity of time measurements refers to the degree of synchronization between information system clocks and reference clocks.
STIG Date
DBN-6300 NDM Security Technical Implementation Guide 2017-09-15

Details

Check Text ( C-76621r1_chk )
Verify the configuration of the NTP server.

Navigate to Settings >> Initial Configuration >> Time.

View the "Time" settings window.

If an NTP server address is not configured, this is a finding.
Fix Text (F-83691r1_fix)
Configure the NTP server on the device. The time difference is part of the NTP protocol and is not configurable.

Navigate to Settings >> Initial Configuration >> Time.

In the "Time" settings window, select the "NTP" button and enter the NTP server address.

Click on "Commit".