Finding ID | Version | Rule ID | IA Controls | Severity |
---|---|---|---|---|
V-76993 | DBNW-DM-000103 | SV-91689r1_rule | Medium |
Description |
---|
If time stamps are not consistently applied and there is no common time reference, it is difficult to perform forensic analysis. |
STIG | Date |
---|---|
DBN-6300 NDM Security Technical Implementation Guide | 2017-09-15 |
Check Text ( C-76619r1_chk ) |
---|
Verify the time zone is configured for "UTC". Navigate to Settings >> Initial Configuration >> Time. View the "Time Zone" box. If the Time Zone is not set to "UTC", this is a finding. |
Fix Text (F-83689r1_fix) |
---|
Configure the time zone to "UTC". Navigate to Settings >> Initial Configuration >> Time and click on "NTP". Click on the drop-down box next to the "Time Zone" label. Select "UTC" underneath the "Etc" category. Click on "Commit". |