The DBN-6300 must compare internal information system clocks at least every 24 hours with an authoritative time server.


Overview

Finding ID Version Rule ID IA Controls Severity
V-76989 DBNW-DM-000100 SV-91685r1_rule Medium
Description
Inaccurate time stamps make it more difficult to correlate events and can lead to an inaccurate analysis. Determining the correct time a particular event occurred on a system is critical when conducting forensic analysis and investigating system events. Sources outside of the configured acceptable allowance (drift) may be inaccurate. Additionally, unnecessary synchronization may have an adverse impact on system performance and may indicate malicious activity. Synchronizing internal information system clocks provides uniformity of time stamps for information systems with multiple system clocks and systems connected over a network.
STIG Date
DBN-6300 NDM Security Technical Implementation Guide 2017-09-15

Details

Check Text ( C-76615r1_chk )
Verify the configuration of the NTP server.

Navigate to Settings >> Initial Configuration >> Time.

View the "Time" settings window.

If an NTP server address is not configured, this is a finding.
Fix Text (F-83685r2_fix)
Configure the NTP server on the device. The time difference is part of the NTP protocol and is not configurable.

Navigate to Settings >> Initial Configuration >> Time.

In the "Time" settings window, select the "NTP" button and enter the NTP server address.

Click on "Commit".