The DBN-6300 must audit the execution of privileged functions.


Overview

Finding ID Version Rule ID IA Controls Severity
V-76985 DBNW-DM-000093 SV-91681r1_rule Medium
Description
Misuse of privileged functions, either intentionally or unintentionally by authorized users, or by unauthorized external entities that have compromised information system accounts, is a serious and ongoing concern and can have significant adverse impacts on organizations. Auditing the use of privileged functions is one way to detect such misuse and identify the risk from insider threats and the advanced persistent threat. With the DBN-6300, audit records are automatically backed up on a real-time basis via syslog when enabled.
STIG Date
DBN-6300 NDM Security Technical Implementation Guide 2017-09-15

Details

Check Text ( C-76611r1_chk )
Verify the DBN-6300 is connected to the syslog server.

Navigate to Settings >> Advanced >> Syslog.

Verify that the syslog services are set to "on", the syslog server information is valid, and the syslog server has connected.

Navigate to Settings >> Advanced >> Audit Log.

Verify that the Audit Syslog, "Use System Syslog" button is set to "Yes" and the Audit Configuration Categories are all checked for Audit Log, Syslog, and Audit Console.

Following this verification, process a privileged function. Confirm the presence of a syslog message on the syslog server containing the privileged function.

If the DBN-6300 is not connected to the syslog server, or if the syslog server is connected but the message containing the information that the privileged function that just occurred is not there, this is a finding.
Fix Text (F-83681r1_fix)
Configure the DBN-6300 to be connected to the syslog server. Also configure the DBN-6300 to include audit records in the syslog message feed.

Navigate to Settings >> Advanced >> Syslog.

Enter the syslog connection information (port and IP address) and push the "enabled" button for both "TCP" and "enable".

Navigate to Settings >> Advanced >> Audit Log.

Verify that the Audit Syslog, "Use System Syslog" button is set to "Yes" and the Audit Configuration Categories are all checked for Audit Log, Syslog, and Audit Console.

If the "Use System Syslog" button is not set to "Yes", press the "Yes" button.

Click on "Commit".