The DBMS must provide a real-time alert when organization defined audit failure events occur.


Overview

Finding ID Version Rule ID IA Controls Severity
V-32378 SRG-APP-000104-DB-000051 SV-42715r1_rule Medium
Description
It is critical for the appropriate personnel to be aware if a system is at risk of failing to process audit logs as required. Audit processing failures include: software/hardware errors, failures in the audit capturing mechanisms, and audit storage capacity being reached or exceeded. If audit log capacity were to be exceeded then events subsequently occurring will not be recorded. Organizations shall define a maximum allowable percentage of storage capacity serving as an alarming threshold (e.g., application has exceeded 80% of log storage capacity allocated) at which time the application or the logging mechanism the application utilizes will provide a warning to the appropriate personnel. A failure of database auditing will result in either the database continuing to function without auditing or in a complete halt to database operations. When audit processing fails, appropriate personnel must be alerted immediately to avoid further downtime or unaudited transactions. This can be an alert provided by the database, a log repository, or the OS when a designated log directory is nearing capacity.
STIG Date
Database Security Requirements Guide 2012-07-02

Details

Check Text ( C-40819r1_chk )
Review DBMS, OS, or third party logging application settings to determine whether a real-time alert will be sent to the appropriate personnel when auditing fails for any reason. If real-time alerts are not sent upon auditing failure, this is a finding.
Fix Text (F-36292r1_fix)
Modify DBMS, OS, or third party logging application settings to send a real-time alert to appropriate personnel when auditing fails for any reason.