UCF STIG Viewer Logo
Changes are coming to https://stigviewer.com. Take our survey to help us understand your usage and how we can better serve you in the future.
Take Survey

All audit records must use UTC or GMT time stamps.


Overview

Finding ID Version Rule ID IA Controls Severity
V-233181 SRG-APP-000374-CTR-000865 SV-233181r599509_rule Medium
Description
The container platform and its components must generate audit records using either Coordinated Universal Time (UTC) or Greenwich Mean Time (GMT) time stamps or local time that offset from UTC. All the components must use the same standard so that the events can be tied together to understand what took place within the overall container platform. Time stamps generated by the container platform and its components must include date and time.
STIG Date
Container Platform Security Requirements Guide 2020-11-24

Details

Check Text ( C-36117r599179_chk )
Review the container platform documentation and configuration files to determine if time stamps for log records can be mapped to UTC or GMT or local time that offsets from UTC.

If the time stamp cannot be mapped to UTC or GMT, this is a finding.
Fix Text (F-36085r599180_fix)
Configure the container platform to use UTC or GMT or local time that offset from UTC based time stamps for log records.