UCF STIG Viewer Logo
Changes are coming to https://stigviewer.com. Take our survey to help us understand your usage and how we can better serve you in the future.
Take Survey

The Cisco switch must be configured to record time stamps for log records that can be mapped to Coordinated Universal Time (UTC) or Greenwich Mean Time (GMT).


Overview

Finding ID Version Rule ID IA Controls Severity
V-220499 CISC-ND-001050 SV-220499r879747_rule Medium
Description
If time stamps are not consistently applied and there is no common time reference, it is difficult to perform forensic analysis. Time stamps generated by the application include date and time. Time is commonly expressed in Coordinated Universal Time (UTC), a modern continuation of Greenwich Mean Time (GMT), or local time with an offset from UTC.
STIG Date
Cisco NX OS Switch NDM Security Technical Implementation Guide 2023-11-28

Details

Check Text ( C-22214r539218_chk )
Review the Cisco switch configuration to verify that it is compliant with this requirement as shown in the example below:

clock timezone EST -5 0

Note: UTC is the default; hence, the command set time-zone may not be seen in the configuration. This can be verified using the show system uptime command.

If the switch is not configured to record time stamps for log records that can be mapped to UTC or GMT, this is a finding.
Fix Text (F-22203r539219_fix)
Configure the Cisco switch to record time stamps for audit records that can be mapped to UTC or GMT as shown in the example below: