UCF STIG Viewer Logo

The Cisco PE switch must be configured to limit the number of MAC addresses it can learn for each Virtual Private LAN Services (VPLS) bridge domain.


Overview

Finding ID Version Rule ID IA Controls Severity
V-221125 CISC-RT-000720 SV-221125r622190_rule Medium
Description
VPLS defines an architecture that delivers Ethernet multipoint services over an MPLS network. Customer Layer 2 frames are forwarded across the MPLS core via pseudowires using IEEE 802.1q Ethernet bridging principles. A pseudowire is a virtual bidirectional connection between two attachment circuits (virtual connections between PE and CE switches). A pseudowire contains two unidirectional label-switched paths (LSP). Each MAC forwarding table instance is interconnected using domain-specific LSPs, thereby maintaining privacy and logical separation between each VPLS domain. When a frame arrives on a bridge port (pseudowire or attachment circuit) and the source MAC address is unknown to the receiving PE switch, the source MAC address is associated with the pseudowire or attachment circuit and the forwarding table is updated accordingly. Frames are forwarded to the appropriate pseudowire or attachment circuit according to the forwarding table entry for the destination MAC address. Ethernet frames sent to broadcast and unknown destination addresses must be flooded out to all interfaces for the bridge domain; hence, a PE switch must replicate packets across both attachment circuits and pseudowires. A malicious attacker residing in a customer network could launch a source MAC address spoofing attack by flooding packets to a valid unicast destination, each with a different MAC source address. The PE switch receiving this traffic would try to learn every new MAC address and would quickly run out of space for the VFI forwarding table. Older, valid MAC addresses would be removed from the table, and traffic sent to them would have to be flooded until the storm threshold limit is reached. Hence, it is essential that a limit is established to control the number of MAC addresses that will be learned and recorded into the forwarding table for each bridge domain.
STIG Date
Cisco NX-OS Switch RTR Security Technical Implementation Guide 2021-03-29

Details

Check Text ( C-22840r409864_chk )
Review the PE switch configuration to determine if a MAC address limit has been set for each VPLS bridge domain.

bridge-domain 100
mac limit maximum addresses nnnnn

If a limit has not been configured, this is a finding.
Fix Text (F-22829r409865_fix)
Configure a MAC address learning limit for each VPLS bridge domain.

SW1(config)# bridge-domain 100
SW1(config-bdomain)# mac limit maximum addresses nnnn
SW1(config-bdomain)# end