The Cisco ISE must send an alarm to one or more individuals when the monitoring collector process has an error or failure.


Overview

Finding ID Version Rule ID IA Controls Severity
V-242628 CSCO-NM-000220 SV-242628r961401_rule Medium
Description
It is critical for the appropriate personnel to be aware if a system is at risk of failing to process audit logs as required. Without an alert, security personnel may be unaware of an impending failure of the audit capability and system operation may be adversely affected. Cisco ISE provides system alarms which notify the administrator when critical system condition occurs. Alarms are displayed in the Alarm dashlet. Administrators can configured the dashlet to receive notification of alarms through e-mail and/or syslog messages. SNMP alerts may also be used to fulfill this requirement.
STIG Date
Cisco ISE NDM Security Technical Implementation Guide 2024-06-10

Details

Check Text ( C-45903r714192_chk )
Verify the Cisco ISE notifies one or more individuals when the monitoring collector process is unable to persist the audit logs generated from the policy service nodes.

1. Choose Administration >> System >> Settings >> Alarm Settings.
2. Select "Log Collector Error" from the list of default alarms and click "Edit".
3. Verify that "Enable" is selected.
4. Select "Enter Multiple Emails Separated with Comma".
5. Verify one or more email addresses are configured.

If "Log Collector Error" alarm type is not enabled or email addresses are not configured to receive the alert, this is a finding.
Fix Text (F-45860r714193_fix)
Configure Cisco ISE to notify one or more individuals when the monitoring collector process is unable to persist the audit logs generated from the policy service nodes.

1. Choose Administration >> System >> Settings >> Alarm Settings.
2. Select "Log Collector Error" from the list of default alarms and click "Edit".
3. Select "Enable".
4. Select "Enter Multiple Emails Separated with Comma".
5. Configure email addresses of individuals to be notified.