UCF STIG Viewer Logo
Changes are coming to https://stigviewer.com. Take our survey to help us understand your usage and how we can better serve you in the future.
Take Survey

The Cisco ISE must be configured to send log data to at least two central log servers for the purpose of forwarding alerts to the administrators and the information system security officer (ISSO).


Overview

Finding ID Version Rule ID IA Controls Severity
V-242661 CSCO-NM-000560 SV-242661r916114_rule Medium
Description
The aggregation of log data kept on a syslog server can be used to detect attacks and trigger an alert to the appropriate security personnel. The stored log data can used to detect weaknesses in security that enable the network IA team to find and address these weaknesses before breaches can occur. Reviewing these logs, whether before or after a security breach, are important in showing whether someone is an internal employee or an outside threat.
STIG Date
Cisco ISE NDM Security Technical Implementation Guide 2023-12-27

Details

Check Text ( C-45936r916085_chk )
To view remote logging targets, complete the following steps:

1. From the ISE Administration Interface, choose Administration >> System >> Logging >> Remote Logging Targets.
2. The Remote Logging Targets page appears with a list of existing logging targets.

If at least two remote logging targets are not configured, this is a finding.
Fix Text (F-45893r916086_fix)
Create at least two Remote Logging Targets and direct logging to those targets. To create an external logging target, complete the following steps:

1. Choose Administration >> System >> Logging >> Remote Logging Targets.
2. Click "Add".
3. Configure the following fields:
- Name - Enter the name of the new target
- Target Type - By default it is set to Syslog. The value of this field cannot be changed.
- Description - Enter a brief description of the new target.
- IP Address - Enter the IP address of the destination machine where you want to store the logs.
- Port - Enter the port number of the destination machine.
- Facility Code - Choose the syslog facility code to be used for logging. Valid options are Local0 through Local7.
- Maximum Length - Enter the maximum length of the remote log target messages. Valid options are from 200 to 1024 bytes.
4. Click "Save".

Go to the Logging Targets page and verify the creation of the new target. To edit a remote logging target, complete the following steps:

1. Choose Administration >> System >> Logging >> Remote Logging Targets.
2. Click the radio button next to the logging target name that you want to edit and click "Edit".
3. Modify the following field values on the Log Collection page as needed.
- Name
- Target Type
- Description
- IP Address
- Port
- Facility Code
- Maximum Length
4. Click "Save".