The Cisco switch must be configured to authenticate SNMP messages using a FIPS-validated Keyed-Hash Message Authentication Code (HMAC).


Overview

Finding ID Version Rule ID IA Controls Severity
V-220552 CISC-ND-001130 SV-220552r879768_rule Medium
Description
Without authenticating devices, unidentified or unknown devices may be introduced, thereby facilitating malicious activity. Bidirectional authentication provides stronger safeguards to validate the identity of other devices for connections that are of greater risk. A local connection is any connection with a device communicating without the use of a network. A network connection is any connection with a device that communicates through a network (e.g., local area or wide area network, Internet). A remote connection is any connection with a device communicating through an external network (e.g., the Internet). Because of the challenges of applying this requirement on a large scale, organizations are encouraged to only apply the requirement to those limited number (and type) of devices that truly need to support this capability.
STIG Date
Cisco IOS XE Switch NDM Security Technical Implementation Guide 2023-11-28

Details

Check Text ( C-22267r508600_chk )
Review the Cisco switch configuration to verify that it is compliant with this requirement as shown in the example below:

snmp-server group V3GROUP v3 auth read V3READ write V3WRITE
snmp-server view V3READ iso included
snmp-server view V3WRITE iso included
snmp-server host x.x.x.x version 3 auth V3USER

Authentication used by the SNMP users can be viewed via the show snmp user command as shown in the example below:

R4#show snmp user

User name: V3USER
Engine ID: 800000090300C2042B540000
storage-type: nonvolatile active
Authentication Protocol: SHA
Privacy Protocol: None
Group-name: V3GROUP

If the Cisco switch is not configured to authenticate SNMP messages using a FIPS-validated HMAC, this is a finding.
Fix Text (F-22256r508601_fix)
Configure the Cisco switch to authenticate SNMP messages as shown in the example below:

SW4(config)#snmp-server group V3GROUP v3 auth read V3READ write V3WRITE
SW4(config)#snmp-server user V3USER V3GROUP v3 auth sha xxxxxxx
SW4(config)#snmp-server view V3READ iso included
SW4(config)#snmp-server view V3WRITE iso included
SW4(config)#snmp-server host x.x.x.x version 3 auth V3USER