UCF STIG Viewer Logo
Changes are coming to https://stigviewer.com. Take our survey to help us understand your usage and how we can better serve you in the future.
Take Survey

The Cisco router must record time stamps for audit records that meet a granularity of one second for a minimum degree of precision.


Overview

Finding ID Version Rule ID IA Controls Severity
V-96305 CISC-ND-001040 SV-105443r1_rule Medium
Description
Without sufficient granularity of time stamps, it is not possible to adequately determine the chronological order of records. Time stamps generated by the application include date and time. Granularity of time measurements refers to the degree of synchronization between information system clocks and reference clocks.
STIG Date
Cisco IOS XE Router NDM Security Technical Implementation Guide 2019-07-25

Details

Check Text ( C-95139r1_chk )
Review the Cisco router configuration to verify that it is compliant with this requirement as shown in the example below.

service timestamps log datetime

If the router is not configured to record time stamps that meet a granularity of one second, this is a finding.
Fix Text (F-101981r1_fix)
Configure the Cisco router to record time stamps that meet a granularity of one second as shown in the example below.

R2(config)#service timestamps log datetime localtime