UCF STIG Viewer Logo
Changes are coming to https://stigviewer.com. Take our survey to help us understand your usage and how we can better serve you in the future.
Take Survey

The Cisco switch must be configured to synchronize its clock with the primary and secondary time sources using redundant authoritative time sources.


Overview

Finding ID Version Rule ID IA Controls Severity
V-220601 CISC-ND-001030 SV-220601r879746_rule Medium
Description
The loss of connectivity to a particular authoritative time source will result in the loss of time synchronization (free-run mode) and increasingly inaccurate time stamps on audit events and other functions. Multiple time sources provide redundancy by including a secondary source. Time synchronization is usually a hierarchy; clients synchronize time to a local source while that source synchronizes its time to a more accurate source. The network device must use an authoritative time server and/or be configured to use redundant authoritative time sources. This requirement is related to the comparison done in CCI-001891. DoD-approved solutions consist of a combination of a primary and secondary time source using a combination or multiple instances of the following: a time server designated for the appropriate DoD network (NIPRNet/SIPRNet); United States Naval Observatory (USNO) time servers; and/or the Global Positioning System (GPS). The secondary time source must be located in a different geographic region than the primary time source.
STIG Date
Cisco IOS Switch NDM Security Technical Implementation Guide 2024-02-02

Details

Check Text ( C-22316r507849_chk )
Review the Cisco switch configuration to verify that it synchronizes its clock with redundant authoritative time sources as shown in the example below:

ntp server x.x.x.x
ntp server y.y.y.y

If the Cisco switch is not configured to synchronize its clock with redundant authoritative time sources, this is a finding.
Fix Text (F-22305r507850_fix)
Configure the Cisco switch to synchronize its clock with redundant authoritative time sources as shown in the example below:

SW2(config)#ntp server x.x.x.x
SW2(config)#ntp server y.y.y.y