UCF STIG Viewer Logo
Changes are coming to https://stigviewer.com. Take our survey to help us understand your usage and how we can better serve you in the future.
Take Survey

The Cisco switch must be configured to record time stamps for log records that can be mapped to Coordinated Universal Time (UTC) or Greenwich Mean Time (GMT).


Overview

Finding ID Version Rule ID IA Controls Severity
V-220603 CISC-ND-001050 SV-220603r521267_rule Medium
Description
If time stamps are not consistently applied and there is no common time reference, it is difficult to perform forensic analysis. Time stamps generated by the application include date and time. Time is commonly expressed in UTC, a modern continuation of GMT, or local time with an offset from UTC.
STIG Date
Cisco IOS Switch NDM Security Technical Implementation Guide 2021-06-02

Details

Check Text ( C-22318r507855_chk )
Review the Cisco switch configuration to verify that it records time stamps for audit records that can be mapped to UTC or GMT as shown in the example below:

service timestamps log datetime localtime
!
hostname R2



clock timezone EST -5

Note: UTC is the default; hence, the command set time zone may not be seen in the configuration. This can be verified using the show system uptime command.

If the switch is not configured to record time stamps for audit records that can be mapped to UTC or GMT, this is a finding.
Fix Text (F-22307r507856_fix)
Configure the Cisco switch to record time stamps for audit records that can be mapped to UTC or GMT as shown in the example below:

SW2(config)#clock timezone EST -5
SW2(config)#service timestamps log datetime localtime