The Central Log Server must be configured to record time stamps for when log records are received by the log server that meet a granularity of one second for a minimum degree of precision.


Overview

Finding ID Version Rule ID IA Controls Severity
V-206505 SRG-APP-000375-AU-000280 SV-206505r855312_rule Low
Description
Without sufficient granularity of time stamps, it is not possible to adequately determine the chronological order of records. Time stamps generated by the application include date and time. Granularity of time measurements refers to the degree of synchronization between information system clocks and reference clocks. Note: The actual configuring and security requirements for NTP is handled in the host OS or NDM STIGs that are also required as part of a Central Log Server review.
STIG Date
Central Log Server Security Requirements Guide 2022-09-14

Details

Check Text ( C-6765r285756_chk )
Examine the configuration.

Verify the Central Log Server records time stamps for when log records are received by the log server that meet a granularity of one second for a minimum degree of precision.

If the Central Log Server is not configured to record time stamps for when log records are received by the log server that meet a granularity of one second for a minimum degree of precision, this is a finding.
Fix Text (F-6765r285757_fix)
Configure the Central Log Server to record time stamps for when log records are received by the log server that meet a granularity of one second for a minimum degree of precision.