UCF STIG Viewer Logo

The Central Log Server must automatically lock the account until the locked account is released by an administrator when three unsuccessful login attempts in 15 minutes are exceeded.


Overview

Finding ID Version Rule ID IA Controls Severity
V-100035 SRG-APP-000345-AU-000400 SV-109139r1_rule Medium
Description
By limiting the number of failed login attempts, the risk of unauthorized system access via user password guessing, otherwise known as brute forcing, is reduced. Limits are imposed by locking the account.
STIG Date
Central Log Server Security Requirements Guide 2020-06-22

Details

Check Text ( C-98885r1_chk )
Examine the configuration.

Verify that the Central Log Server is configured to lock out the account until released by an administrator when 3 consecutive invalid attempts during a 15 minute period is exceeded.

If the Central Log Server is not configured to lock out the account until released by an administrator when 3 consecutive invalid attempts in 15 minutes is exceeded, this is a finding.
Fix Text (F-105719r1_fix)
Configure the Central Log Server to lock out the account until released by an administrator when 3 consecutive invalid attempts during a 15 minute period is exceeded.