Finding ID | Version | Rule ID | IA Controls | Severity |
---|---|---|---|---|
V-251609 | IDMS-DB-000290 | SV-251609r807694_rule | Low |
Description |
---|
Information systems are capable of providing a wide variety of functions and services. Some of the functions and services, provided by default, may not be necessary to support essential organizational operations (e.g., key missions, functions). It is detrimental for software products to provide, or install by default, functionality exceeding requirements or mission objectives. DBMSs must adhere to the principles of least functionality by providing only essential capabilities. |
STIG | Date |
---|---|
CA IDMS Security Technical Implementation Guide | 2022-09-07 |
Check Text ( C-55044r807692_chk ) |
---|
If a CAISAG base installation done with EMPDEMO=YES and/or SQLDEMO=YES, or if a base installation done with CSM and CREATE_DB_DEMO and/or CREATE_SQL_DEMO selected, this is a finding. In OCF/BCF, DISPLAY DMCL In OCF/BCF, DISPLAY DBTABLE In OCF/BCF, DISPLAY SCHEMA DEMOEMPL and DISPLAY SCHEMA DEMOPROJ. If either or both exist, this is a finding. If schema EMPSCHM exists, this is a finding. If any of the following load modules are in load libs used by the installation, this is a finding. EMPSS01, EMPDMCL, EMPLOAD, EMPRPT, EMPINQ If any of the following files are found to be used by the installation, this is a finding. |
Fix Text (F-54998r807693_fix) |
---|
In OCF/BCF, ALTER DMCL Remove load modules EMPSS01, EMPDMCL, EMPLOAD, EMPRPT, and EMPINQ from installation load libraries. Remove files Remove database demo objects from application dictionaries including EMPSCHM and all the record elements and records, EMPSS01, schemas DEMOEMPL, and DEMOPROJ, dropping all the tables in theses schemas. For future base installations, specify EMPDEMO=NO and SQLDEMO=NO for CAISAG installs and do not select CREATE_DB_DEMO and CREATE_SQL_DEMO fields on CSM installs. Note that specified names are default names. Use modified names if they were changed during base installation. |