Finding ID | Version | Rule ID | IA Controls | Severity |
---|---|---|---|---|
BBDS-00-000230 | BBDS-00-000230 | BBDS-00-000230_rule | Medium |
Description |
---|
Security related parameters are those parameters impacting the security state of the system and include parameters related to the implementation of other IA controls. If these controls are not implemented, the system may be vulnerable to a variety of attacks. The use of an MDM allows an organization to assign values to security related parameters across all the devices it manages. This provides assurance that the required mobile OS security controls are being enforced, and that the device user or an adversary has not modified or disabled the controls. It also greatly increases efficiency and manageability of devices in a large scale environment relative to an environment in which each device must be configured separately. |
STIG | Date |
---|---|
BlackBerry Enterprise Service v10.1.x BlackBerry Device Service STIG | 2013-10-25 |
Check Text ( C-BBDS-00-000230_chk ) |
---|
Review the BlackBerry Device Service server policy configuration to determine whether the number of incorrect password attempts before a data wipe procedure is initiated is set to 10. If there are multiple policies, they must all be reviewed. The "Maximum Password Attempt" rule allows the administrator to enforce data wipe upon maximum number of incorrect passwords. Log into BlackBerry Administration Service, and under "BlackBerry solution management" on the left side of the screen, navigate to "Policy > Manage IT policies > |
Fix Text (F-BBDS-00-000230_fix) |
---|
Configure the centrally managed BlackBerry Device Service server policy rule to set the number of incorrect password attempts before a data wipe procedure is initiated to 10. |