UCF STIG Viewer Logo
Changes are coming to https://stigviewer.com. Take our survey to help us understand your usage and how we can better serve you in the future.
Take Survey

The Arista Multilayer Switch must generate audit records when concurrent logons from different workstations occur.


Overview

Finding ID Version Rule ID IA Controls Severity
V-60877 AMLS-NM-000380 SV-75335r1_rule Medium
Description
Without generating audit records that are specific to the security and mission needs of the organization, it would be difficult to establish, correlate, and investigate the events relating to an incident or identify those responsible for one. Audit records can be generated from various components within the information system (e.g., module or policy filter).
STIG Date
Arista MLS DCS-7000 Series NDM Security Technical Implementation Guide 2019-09-30

Details

Check Text ( C-61825r1_chk )
Determine if the network device generates audit records when concurrent logons from different workstations occur.

If the network device does not generate audit records when concurrent logons from different workstations occur, this is a finding.

Verify by reviewing log files to show concurrent logons to the system via the "Show Logging" command.
Fix Text (F-66589r1_fix)
Configure the network device to generate audit records when concurrent logons from different workstations occur.

Enable logging level 6 to ensure this event is captured.

Switch(config)#logging trap 6
switch(config)#logging level all 6