Finding ID | Version | Rule ID | IA Controls | Severity |
---|---|---|---|---|
V-57433 | SRG-APP-000375-AS-000211 | SV-71705r2_rule | Medium |
Description |
---|
To investigate an incident, the log records should be easily put into chronological order. Without sufficient granularity of time stamps, the chronological order cannot be determined. Time stamps generated by the application server include date and time. Granularity of time measurements refers to the degree of synchronization between information system clocks and reference clocks. |
STIG | Date |
---|---|
Application Server Security Requirements Guide | 2020-03-24 |
Check Text ( C-58109r1_chk ) |
---|
Review the application server documentation and configuration files to determine if time stamps for log records meet a granularity of one second. If the time stamp cannot generate to a one-second granularity, this is a finding. |
Fix Text (F-62471r1_fix) |
---|
Configure the application server to use time stamps for log records that can meet a granularity of one second. |