UCF STIG Viewer Logo

The application server must provide the capability to immediately disconnect or disable remote access to the management interface.


Overview

Finding ID Version Rule ID IA Controls Severity
V-57415 SRG-APP-000316-AS-000199 SV-71687r2_rule Medium
Description
Without the ability to immediately disconnect or disable remote access, an attack or other compromise taking progress would not be immediately stopped. The application server must have the capability to immediately disconnect current users remotely accessing the management interface and/or disable further remote access. The speed of disconnect or disablement varies based on the criticality of missions/business functions and the need to eliminate immediate or future remote access to organizational information systems.
STIG Date
Application Server Security Requirements Guide 2019-01-07

Details

Check Text ( C-58091r1_chk )
Review the application server product documentation and server configuration to ensure that there is a capability to immediately disconnect or disable remote access to the management interface.

If there is no capability, this is a finding.
Fix Text (F-62453r1_fix)
Configure the application server to have the capability to immediately disconnect or disable remote access to the management interface.