UCF STIG Viewer Logo

All products must be supported by the vendor or the development team.


Overview

Finding ID Version Rule ID IA Controls Severity
V-70395 APSC-DV-003240 SV-85017r2_rule High
Description
Unsupported commercial and government developed software products should not be used because fixes to newly identified bugs will not be implemented by the vendor or development team. The lack of security updates can result in potential vulnerabilities.
STIG Date
Application Security and Development Security Technical Implementation Guide 2018-12-24

Details

Check Text ( C-70849r1_chk )
Review the application documentation and interview the application administrator.

Identify all software components.

Review the version information and identify the vendor if COTS software.

Access the vendor website to verify the version is still supported.

Ask the application representative for proof that the application and all of its components are supported.

Examples of proof may include:

design documentation that includes support information, support specific contract documentation, successful creation of vendor support tickets, website toll free support phone numbers etcetera.

If any of the software components are not supported by a COTS vendor or a GOTS organization, this is a finding.
Fix Text (F-76631r1_fix)
Remove or decommission all unsupported software products in the application.