UCF STIG Viewer Logo
Changes are coming to https://stigviewer.com. Take our survey to help us understand your usage and how we can better serve you in the future.
Take Survey

The ALG that is part of a CDS must enforce organization-defined one-way information flows using hardware mechanisms.


Overview

Finding ID Version Rule ID IA Controls Severity
V-54493 SRG-NET-000032-ALG-000082 SV-68739r1_rule Medium
Description
Information flow control regulates where information is allowed to travel within a network and between interconnected networks. The flow of all network traffic must be monitored and controlled so it does not introduce any unacceptable risk to the network infrastructure or data. For cross domain solutions, use of hardware enforced flow direction is preferable in high risk environments but is not mandatory. Do not enable any connections between security domains beyond the specified one-way flow. Organization-defined one-way information flows using hardware mechanisms used as part of a CDS system depends on the environment, data, and security boundaries. Organizations implementing CDS must follow the DoD-required process of testing, baselining, and risk assessment to ensure the rigor and accuracy necessary to rely upon a CDS for cross domain security.
STIG Date
Application Layer Gateway Security Requirements Guide 2014-11-03

Details

Check Text ( C-55109r1_chk )
If the ALG is not part of a CDS, this is not applicable.

Verify the ALG is configured to enforce organization-defined one-way information flows using hardware mechanisms.

If the ALG is not configured to enforce organization-defined one-way information flows using hardware mechanisms, this is a finding.
Fix Text (F-59347r1_fix)
If the ALG is part of a CDS, configure the ALG to enforce organization-defined one-way information flows using hardware mechanisms.