UCF STIG Viewer Logo
Changes are coming to https://stigviewer.com. Take our survey to help us understand your usage and how we can better serve you in the future.
Take Survey

ColdFusion must have Event Gateway Services disabled.


Overview

Finding ID Version Rule ID IA Controls Severity
V-62411 CF11-03-000099 SV-76901r1_rule Medium
Description
Application servers provide a myriad of differing processes, features, and functionalities. Some of these processes may be deemed to be unnecessary or too unsecure to run on a production DoD system. Event Gateway Services are used to pass events from external sources to ColdFusion components that are specified. Since this gateway is accepting events from external sources, a listener must be present. When enabled, along with the listener, memory, queues, and processes are available for gateway processes. These resources can be used by an attacker and should be disabled if the feature is not being used for hosted applications.
STIG Date
Adobe ColdFusion 11 Security Technical Implementation Guide 2017-06-15

Details

Check Text ( C-63215r1_chk )
Ask the administrator if Event Gateway services are being used by any hosted applications.

If hosted applications are using the service, this is not a finding.

Within the Administrator Console, navigate to the "Settings" page under the "Event Gateways" menu.

If "Enable ColdFusion Event Gateway Services" is checked, this is a finding.
Fix Text (F-68331r1_fix)
Navigate to the "Settings" page under the "Event Gateway" menu. Uncheck "Enable ColdFusion Event Gateway Services" and select the "Submit Changes" button.